Transformer
Dry type transformer
成功應用案例 +
Product description:
My company is the production of dry type transformer voltage 6kV, 10kV and 35kV. Dry type transformer from the core and high and low voltage winding, company production of transformer by high-quality materials, quality process is chosen professional grade substation safety products, following prominent features:
First, iron core
High quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation material for iron core. (there are also amorphous alloy core transformers using amorphous materials.
Through the selection of the material and grade of the iron core, the control of the cutting and stacking process makes the loss level and the no-load current drop to the lowest, and obtains the very low noise level. An iron core is assembled on the surface of a F or H grade resin to protect from corrosion and dust.
Two, low voltage winding
Low voltage winding to high-quality copper foil winding and, so in case of a short circuit realization of zero axial short-circuit stress; layer between the epoxy thermosetting pre dipped cloth insulation. End winding with thermosetting epoxy prepreg cloth seal. The winding is placed in the oven, heating to 140 DEG C, after 4 hours, winding polymerization as a solid mass, which can guarantee:
The corrosion resistance of the industrial gas - excellent
Insulation resistance - excellent performance
The radial - on the short circuit caused by stress has a very good ability to bear
Low voltage winding terminals for tinned copper, ensure the low-voltage connections without contact interface (such as conductive paste or double sheet metal). The assembly of the low-voltage outlet terminal is completed in accordance with the current mature technology, which comprises a spring pressure washer under the nut and the bolt head.
Three, high voltage coil casting process
The whole process of pouring and curing from the proportion of the epoxy resin mixture is completely controlled by the microcomputer to prevent any human error operation. Aluminum hydroxide and quartz powder stuffing drying in vacuum, degassing and dehumidification, ensure the insulation characteristics of casting body. Under high vacuum and a certain temperature, half of the filler and resin are mixed, the other half is mixed with the curing agent, and the two parts are given. Before the final mixing, two parts of the group will be re carried out once again. Two groups of material in the static mixer to achieve the final mix, then vacuum casting at the optimum temperature. All of the windings are pre heating and degassing after pouring. The curing process selects the best cure temperature curve to complete the gel at 80 C and at the end of the 140. These temperature values are close to the actual transformer operating temperature and mechanical stress is reduced to the minimum (mechanical stress may cause insulator cracks).
Four, performance characteristics
1) low loss, energy efficiency in line with the latest GB20052 first / two energy efficiency standards
2) low noise, better than GB and IEC standards
3) more severe environment / climate test test than C2-E2
(4) global unique, more secure, excellent fire performance (F1 test)
5) global operational verification of high reliability
(6) higher lightning strike resistance level (95kV 10kV)
The main users of the product is widely used in China Southern Power Grid, Inner Mongolia Electric Power Corporation, Shanxi electric power company, Liaoning province power company, Jilin province power company and user engineering and industrial users substation already achieved significant operational performance. Products currently operating in the power grid has more than 10000 units (surface).
technical parameter
Serial number |
Product technical parameters |
Dry type transformer |
|
1 |
Rated voltage |
6KV,12KV,35KV |
|
2 |
Rated capacity |
Below 5000KVA |
|
3 |
Rated frequency |
50HZ(60HZ) |
|
4 |
Insulation grade |
Class F (class H) |
|
5 |
High temperature environment (limit stability) |
+40℃ |
|
6 |
Low temperature environment (limit temperature) |
-25℃ |
|
7 |
Noise standard |
55dB |
|
8 |
Contamination level |
Dust and maintenance free type |
|
9 |
Electric distance |
Greater than 240mm |
|